Art.-Nr.:015010
Treated test tubes for platelet count from venous or capillary blood
Individual test for direct platelet count from capillary blood

The test set consists of:
1 test tube with 1 ml reagent
1 treated end-to-end capillary 20 µl
1 capillary for filling the counting chamber

The blood filled end-to-end capillary is immediately put into the test preparation. After approx. 3 minutes haemolysis occurs, the counting chamber can be filled and after a sedimentation of 10 minutes, counting can be begun in the microscope.

Item no.Description
015010 TTK N 40 n
Packing unit: 50 pcs in bag
2 ml, Ø 11 mm, L = 40 mm

Art.-Nr.: 015110
Treated test tubes for platelet count from venous or capillary blood
Individual test for direct platelet count from venous blood

The test set consists of:
1 test tube with 1 ml reagent
1 capillary for filling the counting chamber

When the blood has been added to the test preparation, haemolysis occurs after approx. 3 minutes, the counting chamber can be filled, and after a sedimentation of 10 minutes, counting can be begun in the microscope.

Item no.Description
015110 TTV N 40 n
Packing unit: 50 pcs in bag
2 ml, Ø 11 mm, L = 40 mm

Art.-Nr.:017005
Treated test tubes for reticulocyte count from venous or capillary blood in a ratio of 1:1 or 2:1
Test tubes with 100 µl staining solution for reticulocyte count from venous or capillary blood

The sample material is added to the staining solution in the desired ratio, mixed gently, and after 20 - 30 minutes the smear can be made.

Item no.Description
017005 R 40 n standing rim
Packing unit: 100 pcs in bag
2 ml, Ø 11mm, L = 40 mm


Recommendation: For applying the mixture of blood and staining solution to the microscopic slide we recommend the capillary for filling the counting chamber (item no. 015302).

Art.-Nr.:017010
Treated test tubes for reticulocyte count from venous or capillary blood in a ratio of 1:1 or 2:1
Individual test for reticulocyte count from capillary blood

The test set consists of:
1 test tube with 50 µl staining solution
1 treated end-to-end capillary 50 µl

The sample material is added to the staining solution in the desired ratio, mixed gently, and after 20 - 30 minutes the smear can be made.

Item no.Description
017010 GK R 30
Packing unit: 100 pcs in bag
0,7 ml, Ø 11/8 mm, L= 29 mm


Recommendation: For applying the mixture of blood and staining solution to the microscopic slide we recommend the capillary for filling the counting chamber (item no. 015302).